Low Voltage Distribution Board

Shop our high-quality Low Voltage Distribution Boards directly from the factory. Our boards are reliable, efficient, and meet industry standards. Get yours today!

Request a Quote
  • Low Voltage Distribution Board

PRODUCTS DETAILS

JP Low Voltage Distribution Board

The JP intelligent integrated distribution board produced by ROOQ integrates reactive power compensation, electric energy measurement, outgoing line protection, load distribution, on-line monitoring and station area management. It has the functions of remote data transmission and intelligent control. It is suitable for the installation and use of low-voltage side of distribution transformer on the pole of urban and rural power grid.


Executive standard

IEC 60439-1 Low voltage switchgear and control-gear assemblies

Part 1:Type test and partial type test assemblies

GB 7251.1 Low voltage switchgear and controlgear assemblies

Part 1: type test and partial type test assemblies

JB/T 9661-1999 Low voltage withdrawable switchgear and other standards


Service Environment

Installation location: Outdoor

Ambient air temperature:

The ambient air temperature shall be less than +45°C, and the average temperature within 24 hours shall be less than+35°C. The min ambient air temperature is -40°C.

The maximum temperature in the container shall be less than +65℃.

Altitude: The altitude of the installation site shall not exceed 2000m

Humidity:

The daily average relative humidity shall be less than 95%; When the maximum temperature is + 25 ℃, the relative humidity can be as high as 100% (including condensation) in a short time

Pollution level: meet the pollution level 4 specified in GB


Technical Data

Model

Rated
Capacity
(kVA)

Circuits

Power distribution

Reactive power compensation

Measurement(L×W×H)
mm

Incoming
Knife switch

Main Bus-bar
TYM

Integrated
protector

Compensation capacity(kvar)

Capacitance
grouping

JP-125/3-N

80、100、
125

3

400A

30×3

100A

20

Y5+△5+△10

1300×
600×1200

JP-200/3-N

160、200

3

400A

40×4

200A

40

Y5+△5
+△10+△20

JP-250/3-N

250

3

600A

50×5

250A

50

Y10+△5
+△15+△20

1600×600×1200

JP-315/3-N

315

3

1000A

60×6

400A

65

Y10+△10
+△20+△25



Model

Rated
Capacity
(kVA)

Circuits

Power distribution

Reactive power compensation

Measurement(L×W×H)
mm

Incoming
Knife switch

Main Bus-bar
TYM

Integrated
protector

Compensation capacity(kvar)

Capacitance
grouping

JP-125/2-N

80、100、125

2

400A

30×3

200A

20

Y5+△5+△10

1300×
600×1200

JP-200/2-N

160、200

2

600A

40×4

250A

40

Y5+△5+△10+△20

JP-315/2-N

250、315

2

1000A

60×6

400A

60

Y10+△10
+△20+△20

1600×600×1200



image003


Hot Products

Single Phase Oil Transformer

Single Phase Oil Transformer

3 Phase Auto Transformer

3 Phase Auto Transformer

Vauum Load Switch

Vauum Load Switch

Low Voltage Distribution Board

Low Voltage Distribution Board

Toroidal Transformer

Toroidal Transformer

Indoor Vacuum Circuit Breaker

Indoor Vacuum Circuit Breaker

VS1 Vacuum Circuit Breaker

VS1 Vacuum Circuit Breaker

ZW8-12 Automatic Circuit Recloser

ZW8-12 Automatic Circuit Recloser

Outdoor Vacuum Circuit Breaker

Outdoor Vacuum Circuit Breaker

Padmount Substation

Padmount Substation

33KV Transformer

33KV Transformer

3 Phase Isolation Transformer

3 Phase Isolation Transformer

Cable Distribution Cabinets

Cable Distribution Cabinets

Dry Type Transformer With On Load Tap Changer

Dry Type Transformer With On Load Tap Changer

Contact us