The three phase pad mounted distribution transformers provide a reliable and affordable solution for clients who need to reduce their overall operating costs. They are low-profile, compartment-type transformers, which are generally used for step-down purposes from an underground primary cable supply suitable for mounting outdoors on pads without additional protective enclosures, and meet the following standard: IEC60076, ANSI/IEEEC57.12.00, C57.12.20,C57.12.38, C57.12.90, BS171, SABS 780 etc.
Execute Standard
IEEE Std C57.12.00 – Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers.
IEEE Std C57.12.28 – Pad-Mounted Equipment - Enclosure Integrity.
IEEE Std C57.12.34 – Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers
IEEE Std C57.12.90– Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short-Circuit Testing of Distribution and Power Transformers.
IEEE Std C57.12.91 – Guide for Loading Mineral-Oil-Immersed Transformers.
Service Condition
Type: Both indoor or outdoor
Air temperature:
Maximum temperature: +40℃; Minimum temperature:-25℃
Relative Humidity:
Monthly average humidity 95%; Daily average humidity 90%.
Altitude above sea level: ≤2000m
Ambient air not apparently polluted by corrosive and flammable gas,
Earthquake intensity: 8 degrees
Pollution level: III
Technical data
No. | Model | HV | Transformer | LV | Measurement (L×W×H) | ||
Incoming | Outgoing | Capacitor | |||||
1 | ZGS11-80/10 | Terminal | S11-80kVA | Load Switch | MCB 2-3circuits | No | 2000*1500*1950 |
RMU | 2200*1500*1950 | ||||||
2 | ZGS11-100/10 | Terminal | S11-100kVA | Load Switch | MCB 2-3circuits | Dynamic compensation | 2000*1500*1950 |
RMU | 2200*1500*1950 | ||||||
3 | ZGS11-200/10 | Terminal | S11-200kVA | Load Switch | MCB 3-4circuits | Dynamic compensation | 2200*1600*1950 |
RMU | 2200*1600*1950 | ||||||
4 | ZGS11-315/10 | Terminal | S11-315kVA | Load Switch | MCB 3-4circuits | Dynamic compensation | 2200*1600*1950 |
RMU | 2200*1600*1950 | ||||||
5 | ZGS11-400/10 | Terminal | S11-400kVA | Load Switch | MCB 3-4circuits | Dynamic compensation | 2200*1600*1950 |
RMU | 2200*1600*1950 | ||||||
6 | ZGS11-500/10 | Terminal | S11-500kVA | Load Switch | MCB 3-4circuits | Dynamic compensation | 2200*1600*1950 |
RMU | 2200*1600*1950 | ||||||
7 | ZGS11-630/10 | Terminal | S11-630kVA | Load Switch | MCB 4-6circuits | Dynamic compensation | 2200*1700*1950 |
RMU | 2300*1700*1950 | ||||||
8 | ZGS11-800/10 | Terminal | S11-800kVA | Load Switch | MCB 4-6circuits | Dynamic compensation | 2400*1800*1950 |
RMU | 2400*1800*1950 | ||||||
9 | ZGS11-1000/10 | Terminal | S11-1000kVA | Load Switch | MCB 4-6circuits | Dynamic compensation | 2400*1800*1950 |
RMU | 2400*1800*1950 | ||||||
10 | ZGS11-1250/10 | Terminal | S11-1250kVA | Load Switch | MCB 4-6circuits | Dynamic compensation | 2600*1800*1950 |
RMU | 2600*1800*1950 |