Vauum Load Switch

Looking for a reliable vacuum load switch? Look no further! We are a factory specializing in producing high-quality vacuum load switches. Contact us today!

Request a Quote
  • Vauum Load Switch

PRODUCTS DETAILS

FZN25-12, FZRN25-12 vacuum load switch and its combination appliance are applicable to three-phase AC 50Hz ring main unit or terminal power supply and industrial electrical equipments for load control and short circuit protection. AC high-voltage vacuum load switch is mainly composed of frame, disconnector, vacuum arc extinguishing chamber, grounding switch, spring operating mechanism, etc. The AC high-voltage vacuum load switch is compact in structure, small in size, long in life, making and closing, strong in breaking capacity, and simple in operation and maintenance. The AC high-voltage vacuum load switch is equipped with spring operation. The motor spring energy storage and closing modes are electromagnet closing and manual opening and closing. The disconnector, vacuum switch and grounding switch are interlocked (mechanical interlocking) to prevent misoperation.


FZN25 and FZRN25 can realize one-time operation of isolating fracture and arc extinguishing chamber fracture.

FZN25-12 and FZRN25-12 have a grounding valve which is interlocked with the grounding switch between the static contact and the moving contact conductor, ensuring safety and facilitating maintenance.


Item

Units

Technical Data

FZN25- 12D/T630-20

FZRN25- 12D/T125-31.5

Rated voltage

KA

12

Rated frequency

HZ

50

Rated Current

A

630

125

Rated insulation level

1min power frequency withstand voltage

KV

Arc chamber between open contacts 30:
To earth, phase to phase 42;
Isolation between open contacts 48

Lightning impulse withstand voltage

KV

To earth ,phase to phase 75:
Isolation between open contact :85

Rated peak withstand curent

KA

50

-

Rated short-time withstand current

KA

20

-

Rated active load breaking current

A

630

125

Rated closed-Loop breaking current

A

630

125

Rated cable charging breaking current

A

10

10

Rated breaking no-load transformer capacity

KVA

1250

1250

Rated short-circuit breaking current

KA

-

31.5

Rated transfer current

A


2000

Fuse Model


-

SDLAJ- 12SFLAJ-12

Impactor outputs energy

J

-

2-5

Rated short circuit making current

KA

50

Earthing switch rated peak withstand current


50

Earthing switch rated short-time withstand current

KA

20

Auxiliary circuit rated voltage

V

AC/CD220;110

Mechanical life

times

1000


The main models of FZN25-12 series high-voltage vacuum load switch products include:

FZN25-12/630-20, FZN25-12D/630-20, FZN25-12R/630-20, FZRN25-12D/T125-31.5

FZN25-12RD/1250-31.5, FZN25-12RD/1000-31.5, FZN25-12D/630-20

FZN25-12/t630-20, FZN25-12/t1250-31.5, FZN25-12/630A


image001

image003

image005

1

image011


Hot Products

Single Phase Pad Mounted Transformer

Single Phase Pad Mounted Transformer

Oil Filled Transformer

Oil Filled Transformer

Withdrawable Switchgear

Withdrawable Switchgear

Indoor Vacuum Circuit Breaker

Indoor Vacuum Circuit Breaker

KYN28 Switchgear

KYN28 Switchgear

ZW8-12 Automatic Circuit Recloser

ZW8-12 Automatic Circuit Recloser

Low Voltage Distribution Board

Low Voltage Distribution Board

SGB Dry Type Transformer

SGB Dry Type Transformer

VS1 Vacuum Circuit Breaker

VS1 Vacuum Circuit Breaker

HXGN-12 AC Enclosed Metal Switchgear

HXGN-12 AC Enclosed Metal Switchgear

Pad Mounted Distribution Transformer

Pad Mounted Distribution Transformer

Single Phase Auto Transformer

Single Phase Auto Transformer

Mns Electrical Board

Mns Electrical Board

Single Phase Isolation Transformer

Single Phase Isolation Transformer

Contact us