3 Phase Isolation Transformer

Looking for a reliable factory for a 3 phase isolation transformer? Look no further! Our high-quality products ensure efficient and safe energy distribution.

Request a Quote
  • 3 Phase Isolation Transformer
  • 3 Phase Isolation Transformer
  • 3 Phase Isolation Transformer
  • 3 Phase Isolation Transformer

PRODUCTS DETAILS

General (SBK series three-phase dry type isolation transformer)

SBK series three - phase dry type transformer adopts high quality material and advanced technology, it has advantages of damp - proof and convenient maintenance, it can be applied to such power transmission and distribution places like underground railway, high building, airport, station, wharf, enterprise, tunnel, etc. It is mainly used in power supply occasions of AC 50~60Hz and voltage less than 1000V. All the input and output voltage, connection group and capacity of tapped winding can be designed and produced according to users' requirements.


Working conditions

The transformer could operate unfailingly under following condition.

1. Sea level altitude is lower than 2500M

2. Air temperature: not higher than 40ºC, and not lower than -25 ºC

3. Relative humidity: monthly average humidity is 90%.

4. A medium of no explosion hazard in where no air might corrode metal and destroy insulation, or no conductive dust existing.

5. A place of no weather effect.


Installation and use instruction

1. Unfold packing case, take out instruction, spare parts and the unit, and read “Operating instruction” carefully to ensure correct operation.

2. Fasten the transformer firmly on suitable place of airiness and heat emission to prevent it from vibration or corrosion.

3. Please test if circuitry voltage and mains voltage is rated input voltage before use it. The allowable deviation is ±5%. Please add a regulated power supply on front terminal to ensure reliable operation of transformer if the tested voltage exceeds allowable range consumedly.

4. Select lead of proper cross section and connect it according to indication, make contact after confirmed that load sharing is inerrant. For selection of cross section of lead under different conditions, please refer to following sheet:


Rated input/output current (A)

Cross section of lead (copper) (mm²)

5

0.75

5-10

1.00

10-16

1.50

16-25

2.50

25-32

4.00

32-45

6.00

45-63

10.00

63-80

16.00

80-110

25.00

110-130

35.00

130-170

50.00

170-220

70.00

220-270

95.00


Calculating formula of rated current:

Current=Rated capability (VA)/rated output (input) voltage (V) *A


Precautions

Before purchase, please estimate total capacitance of applicable electric appliance, and choose transformer that has equivalent capacitance to prevent transformer from burning of instantaneous startup.

1.The transformer is designed and produced strictly according to relevant national standard. When using duplex winding and multi-control voltage (tap style), such as BK, JMB transformer please respectively reduce capability according to max voltage radio of primary and secondary voltage, namely, current may not exceed calculated value of max voltage; For transformer that adopts winding to divide power capacity, it is necessary to control power capacity of each winding strictly to prevent transformer from burning. For configuration and character of winding, please refer to figure 1.

2.Before installation, please check if all data listed on nameplate meet your requirement, and perform installation after confirmation.

3.After electrified, radiation (the temperature should not exceed 80℃ ) with iron core and coil of transformer is normal. If the temperature exceed 80℃, or condition of smoking occurs, please shut off power, check capacitance of electric appliance, and adjust it.


Three-phase Configuration and character of control transformer winding

image002Character of duplex winding tap style is shown as figure 1. Primary and secondary winding of transformer respectively change voltage value with lead tap of the same specification, set high-pressure level as rated value, reduce capability according to dropping radio of voltage. In case that use two kinds of voltage at output terminal synchronously, the current valued should not be exceeded (Current is rated value.)
image004Character of multi windings of fractional power is shown as figure 2. There is one winding at primary winding, and various windings at negative pole that loads separately, hereby, each winding should not exceed specified value.  
image006Character of composite winding of fractional power is shown as figure 3. It has these two characters abovementioned, in case that change 380V of primary level to 220V, transformer capacitance should be 0.578 time of original value, current of output winding should not exceed 0.578 time of original value. 


Configuration introduction

For configuration type, please refer to figure1 and figure2.

image003_


1. Adopt three pillar iron core that made of cold rolled silicon steel plate, flux density ≥ 12000 gauss

2. According to capability, the winding will adopt SBECR double fiberglass packed flat copper wire, QZ high strength enameled wire or copper bar.

3. Insulation level: level B

Basic parameter

1. Apply to circuit below 50HZ 1000V

2. Rated working system: short term working system and long term working system.

3. Major capability, please refer to Sheet 1


SN

Specification and capability

SN

Specification and capability

1

SG/SBK-300VA

14

SG/SBK-8000 VA

2

SG/SBK-500 VA

15

SG/SBK-10KVA

3

SG/SBK-750 VA

16

SG/SBK-15 KVA

4

SG/SBK-1000 VA

17

SG/SBK-20 KVA

5

SG/SBK-1500 VA

18

SG/SBK-25 KVA

6

SG/SBK-2000 VA

19

SG/SBK-30 KVA

7

SG/SBK-2500 VA

20

SG/SBK-40 KVA

8

SG/SBK-3000 VA

21

SG/SBK-50 KVA

9

SG/SBK-3500 VA

22

SG/SBK-60 KVA

10

SG/SBK-4000 VA

23

SG/SBK-100 KVA

11

SG/SBK-5000 VA

24

SG/SBK-150 KVA

12

SG/SBK-6000 VA

25

SG/SBK-200 KVA

13

SG/SBK-7000 VA

26

SG/SBK-300 KVA


Please select combination of rated power voltage and rated output voltage according to Sheet 2 preferentially.Sheet 2


Rated power voltage

Rated output voltage

660 380 220 127

380 220 127 110 36 24 12 6



Hot Products

Vauum Load Switch

Vauum Load Switch

Low Voltage Distribution Panel

Low Voltage Distribution Panel

Amorphous Alloy Transformer

Amorphous Alloy Transformer

SGB Dry Type Transformer

SGB Dry Type Transformer

Single Phase Isolation Transformer

Single Phase Isolation Transformer

Toroidal Transformer

Toroidal Transformer

VS1 Vacuum Circuit Breaker

VS1 Vacuum Circuit Breaker

Pad Mounted Distribution Transformer

Pad Mounted Distribution Transformer

Single Phase Pad Mounted Transformer

Single Phase Pad Mounted Transformer

Padmount Substation

Padmount Substation

Single Phase Auto Transformer

Single Phase Auto Transformer

Oil Filled Transformer

Oil Filled Transformer

GCK Switchgear

GCK Switchgear

ZW8-12 Automatic Circuit Recloser

ZW8-12 Automatic Circuit Recloser

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours